Standard Details express typical University requirements, and thus should be used in place of the equivalent A/E detail. Professional judgment is required to make Standard Details project specific.
To filter to these specific sections type the appropriate section into the Search bar below (i.e. 9.0, 9.1, 9.2, etc.)
9.0 - General Details
9.1 - Architectural Details
9.2 - Mechanical Details
9.3 - Electrica Details
9.4 - Site/Civil Details - See UM AEC Site/Civil Details
9.5 - Interior Design Details
9.6 - Construction Services Details - These details are for projects managed by Construction Services Details
(Click here to report a broken or missing link)
Section Number | Detail Number | Detail Name | Download DWG | View PDF | |
---|---|---|---|---|---|
9.0 General | D-1 | Standard ANSI D-Size Coversheet | |||
9.0 General | D-1 | Standard ANSI D-Size Titleblock | |||
9.0 General | A-1 | Standard A-Size Covrsheet | |||
9.0 General | A-1 | Standard A-Size Titleblock | |||
9.0 General | E-1 | Standard ARCH E-Size Coversheet | |||
9.0 General | E-1 | Standard ARCH E-Size Titleblock | |||
9.1 Architectural | D064040H-1 | Counter at Soiled Utility | |||
9.1 Architectural | D064040H-2 | Plastic Laminate Counter with Grommet | |||
9.1 Architectural | D064040H-3 | Standard Workstation Counter | |||
9.1 Architectural | D064040H-4a | Pull Out Waste/Linen Cabinet - Plan & Elevation | |||
9.1 Architectural | D064040H-4b | Pull Out Waste/Linen Cabinet - Section | |||
9.1 Architectural | D064040H-4c | Standard Base Cabinet Leg Leveler | |||
9.1 Architectural | D064040H-5 | Sink Counter in Patient Room - Elevation & Section | |||
9.1 Architectural | D064040H-6 | Clerk Station Elevations | |||
9.1 Architectural | D064040H-7a | Privacy Panel - Elevation | |||
9.1 Architectural | D064040H-7b | Privacy Panel - Sections | |||
9.1 Architectural | D064040H-8 | Standard Multi-Person Office Aisle Clearances | |||
9.1 Architectural | D081100H-1 | Head/Jamb | |||
9.1 Architectural | D102800H-1 | Alcohol Based Hand Rub Sanitizers Mounting Requirements | |||
9.1 Architectural | D064040H-10 | Interstitial Waterproofing LMPM 'A' Duct Penetration | |||
9.1 Architectural | D064040H-11 | Interstitial Waterproofing LMPM 'B' Duct Penetration | |||
9.1 Architectural | D064040H-12 | Interstitial Waterproofing LMPM 'C' Duct Penetration | |||
9.1 Architectural | D064040H-13 | Interstitial Waterproofing LMPM 'D' Duct Penetration | |||
9.1 Architectural | D064040H-14 | Interstitial Waterproofing LMPM 'E' Duct Penetration | |||
9.1 Architectural | D064040H-15 | Interstitial Waterproofing LMPM 'F' Duct Penetration | |||
9.1 Architectural | - | Infection Control Room Types - See SBA 5.13 | See Comments | See Comments | |
9.2 Mechanical | N/A | CLICK HERE to See UM AEC Mechanical Details | |||
9.2 Mechanical | D221113H-1 | Pipe Sleeve Thru Floor | |||
9.2 Mechanical | D221113H-2 | Pipe Sleeve Thru Interior Wall | |||
9.2 Mechanical | D221113H-3 | Typical Main Pipe Tapping | |||
9.2 Mechanical | D230041H-1 | Inline Pump Piping Diagram | |||
9.2 Mechanical | D220010H-1 | Typical Mixing Valve | |||
9.2 Mechanical | D220010H-2 | Typical Ice Machine Piping Detail | |||
9.2 Mechanical | D226000H-1 | EVAC Outlet Diagram | |||
9.2 Mechanical | D226000H-2 | Standard Medical Gas Zone Valve Sign | |||
9.2 Mechanical | D226000H-3 | Standard Medical Gas Alarm Panel Sign | |||
9.2 Mechanical | D230020H-1 | Duct Elbow | |||
9.2 Mechanical | D230020H-2 | Typical Interstitial Level Terminal Box Installation | |||
9.2 Mechanical | D230020H-3 | Typical Interstitial Level Duct Support | |||
9.2 Mechanical | D233600H-1 | Typical Terminal Box Installation | |||
9.2 Mechanical | D230905H-1 | Thermostat Mounting Detail | |||
9.2 Mechanical | D230905H-2 | Typical Pneumatic VAV Unit w/ Reheat Coil & Tracking Return Control Diagram - UH | |||
9.2 Mechanical | D230905H-3 | Typical Pneumatic VAV Unit w/ Reheat Coil Control Diagram - UH | |||
9.2 Mechanical | D230905H-4 | Typical Pneumatic VAV Unit w/ Reheat Coil Control Diagram - THC & MCHC | |||
9.2 Mechanical | D230905H-5 | Typical VAV Unit w/ Reheat Coil & Tracking Return Control Diagram - CC | |||
9.2 Mechanical | D230905H-6 | Typical Dual Duct CAV Unit Control Diagram - MOTT | |||
9.2 Mechanical | D230905H-7 | Typical DDC VAV Unit w/ Reheat Coil Control Diagram - Retrofit in Existing UMH Facilities | |||
9.2 Mechanical | D230905H-8 | Typical DDC VAV Unit w/ Reheat Control & Tracking Return Diagram - Retrofit in Existing UH Facility | |||
9.2 Mechanical | D230905H-9 | Typical DDC VAV Unit w/ Reheat Control - Retrofit in Existing C&W Facility | |||
9.2 Mechanical | D230905H-10 | Fan Coil Unit Control Diagram | |||
9.2 Mechanical | D230905H-11 | Typical DDC Panel Assembly | |||
9.2 Mechanical | D230905H-12a | Building Management System Network Architecture | |||
9.2 Mechanical | D230905H-12b | Building Management System Network Architecture for Children's & Women's Building #5173 ONLY | |||
9.2 Mechanical | D230905H-13a | Monitoring Points, Alarm & Trend Requirements (Mechanical Equipment) | |||
9.2 Mechanical | D230905H-13b | Monitoring Points, Alarm & Trend Requirements (Applications) | |||
9.3 Electrical | D260913H-1 | Monitoring Points, Alarm & Trend Requirements (Power Monitoring) | |||
9.3 Electrical | N/A | CLICK HERE to See UM AEC Electrical Details | |||
9.3 Electrical | D272000H-1 | Data Connection to Equipment Panels up to 120V | |||
9.3 Electrical | D272000H-2 | Data Connection to Equipment Panels Above 120V up to 480V | |||
9.3 Electrical | D274116H-1 | Audio-Visual Infrastructure Requirements for G1 & G2 Rooms | |||
9.3 Electrical | E-1 | Audio Visual Infrastructure Requirements for Digital Signage; 43 inch, 49 inch & 55 inch Screens on Stud Wall | |||
9.3 Electrical | E-2 | Audio Visual Infrastructure Requirements for Digital Signage; Surface Mount and Suspended Pole Raceway | |||
9.3 Electrical | E-IP-1 | Isolated Power System Requirements; Key Notes, Device Wiring, and Raceway Method Details | |||
9.3 Electrical | E-IP-2 | Isolated Power System Requirements; Receptacle & Boom Wiring, and Ground Loop Wiring Schedule Details | |||
9.3 Electrical | N/A | Card Reader (Request from FPD Lead for your project) | |||
9.3 Electrical | N/A | Card Reader - CVC - (Request from FPD Lead for your project) | |||
9.4 Site/Civil | N/A | For Site/Civil Details CLICK HERE to See UM AEC Civil/Site Details | |||
9.5 Interior Design | Option A - Maple | Universal Air Touch - Maple | |||
9.5 Interior Design | Option A - Cherry | Universal Air Touch - Cherry | |||
9.5 Interior Design | Option B - Maple | Universal Extended Corner B - Maple | |||
9.5 Interior Design | Option B - Maple | Universal Extended Corner B - Cherry | |||
9.5 Interior Design | Option B - Maple | Universal Run Off Bullet - Maple | |||
9.5 Interior Design | Option B - Maple | Universal Run Off Bullet - Cherry | |||
9.5 Interior Design | Option B - Maple | Universal Extended Corner A - Maple | |||
9.5 Interior Design | Option B - Maple | Universal Extended Corner A - Cherry | |||
9.6 Construction Services - Arch | A-0 | Architectural Standard Legend Sheet | |||
9.6 Construction Services - Arch | D06040H-1 | Counter at Soiled Utility | |||
9.6 Construction Services - Arch | D06040H-2 | Plastic Laminate Counter with Grommet | |||
9.6 Construction Services - Arch | D06040H-3 | Standard Workstation Counter | |||
9.6 Construction Services - Arch | D06040H-4a | Pull Out Waste/Linen Cabinet - Plan & Elevation | |||
9.6 Construction Services - Arch | D06040H-4b | Pull Out Waster/Linen Cabinet - Section | |||
9.6 Construction Services - Arch | D06040H-5 | Sink Counter in Patient Room - Elevation & Section | |||
9.6 Construction Services - Arch | D06040H-6 | Clerk Station Elevations | |||
9.6 Construction Services - Arch | D06040H-7a | Privacy Panel - Elevation | |||
9.6 Construction Services - Arch | D06040H-7b | Privacy Panel - Sections | |||
9.6 Construction Services - Arch | D06040H-8 | Standard Multi-Person Office Aisle Clearances | |||
9.6 Construction Services - Arch | D102800H-1 | Corridor Mounting Requirements | |||
9.6 Construction Services - Mech | M-0 | Mechanical Standard Legend Sheet | |||
9.6 Construction Services - Mech | D221113H-1 | Pipe Sleeve Thru Floor | |||
9.6 Construction Services - Mech | D221113H-2 | Pipe Sleeve Thru Interior Wall | |||
9.6 Construction Services - Mech | D15160-001 | End Suction Pump Installation Detail | |||
9.6 Construction Services - Mech | D15160-002 | Pump Base Installation Detail | |||
9.6 Construction Services - Mech | D15160-003 | Vertical Split Case Pump Installation Detail | |||
9.6 Construction Services - Mech | D15160-005 | Vertical Split Case Pump Installation Detail | - | ||
9.6 Construction Services - Mech | D15160-006 | End Suction Pump Installation Detail | - | ||
9.6 Construction Services - Mech | D220010H-1 | Typical Mixing Valve | |||
9.6 Construction Services - Mech | D220010H-2 | Ice Machine Piping Detail | |||
9.6 Construction Services - Mech | D15515-002 | Automatic Water System Air Vent Detail | |||
9.6 Construction Services - Mech | D15820-001 | Hot Water Heating Coil 2-way Control Valve Detail | |||
9.6 Construction Services - Mech | D15820-002 | Hot Water Heating Coil 3-way Control Valve Detail | |||
9.6 Construction Services - Mech | D15820-101 | Chilled Water Cooling Coil 3-way Control Valve Detail | - | ||
9.6 Construction Services - Mech | D15820-102 | Chilled Water Cooling Coil 2-way Control Valve Detail | - | ||
9.6 Construction Services - Mech | D15820-201 | Steam Heating Coil | - | ||
9.6 Construction Services - Mech | D15830-001 | Draw-Thru Coil Condensate Drain | - | ||
9.6 Construction Services - Mech | D15830-002 | Blow-Thru Coil Condensate Drain | - | ||
9.6 Construction Services - Mech | D15830-101 | Duct-Mounted Reheat Coil - Hot Water Heating Piping Connections Detail | - | ||
9.6 Construction Services - Mech | D230022H-FPD-1 | Supply Air Diffuser with Flex Duct | - | ||
9.6 Construction Services - Mech | D230022H-FPD-2 | Return/Exhaust Air Grille | - | ||
9.6 Construction Services - Mech | D230022H-FPD-4 | Fire Damper - Wall Installation | - | ||
9.6 Construction Services - Mech | D230022H-FPD-5 | Fire Damper - Floor Installation | - | ||
9.6 Construction Services - Mech | D230020H-1 | Duct Elbow | |||
9.6 Construction Services - Mech | D230020H-2 | Typical Interstitial Level Box Installation | |||
9.6 Construction Services - Mech | D230020H-3 | Typical Interstitial Level Duct Support | |||
9.6 Construction Services - Mech | D230020H-FPD-1 | Typical Duct Tap | - | ||
9.6 Construction Services - Mech | T15890-001 | Sample Duct Construction Schedule | - | ||
9.6 Construction Services - Mech | T15895-001 | Sample Damper Construction Schedule | - | ||
9.6 Construction Services - Mech | D230021H-1 | Typical Terminal Box Installation | |||
9.6 Construction Services - Mech | D15975-001 | DP Sensor Detail | - | ||
9.6 Construction Services - Elec | E-0 | Electrical Standard Legend Sheet | - | ||
9.6 Construction Services - Elec | D260533H-FPD-1 | Conduit Penetration at Interior Gyp. Board Wall | - | ||
9.6 Construction Services - Elec | D260533H-FPD-2 | Conduit Penetration at Interior Concrete/ CMU Wall | - | ||
9.6 Construction Services - Elec | D260533H-FPD-3 | Conduit Sleeve Thru Exterior Wall | - | ||
9.6 Construction Services - Elec | D260533H-FPD-4 | Conduit Sleeve Thru Floor | - | ||
9.6 Construction Services - Elec | D260533H-FPD-5 | Typical Dual Channel Wireway for Existing Walls | - | ||
9.6 Construction Services - Elec | D265100H-FPD-1 | Lay-in Grid Fluorescent Luminaire | - | ||
9.6 Construction Services - Elec | D265100H-FPD-2 | Downlight Luminaire | - | ||
9.6 Construction Services - Elec | D265100H-FPD-3 | Exit Luminaire | - | ||
9.6 Construction Services - Elec | - | Card Reader - Request from FPD Lead | - | ||
9.6 Construction Services - Elec | - | Card Reader - CVC - Request from FPD Lead | - | ||
9.6 Construction Services - Elec | D281600H-FPD-1 | Camera Ceiling Mount | - | ||
9.6 Construction Services - Elec | D272000H-FPD-1 | Typical Communication/ Data Outlet Installation | - |